Electric Induction hobs Chef’s EH-MIX544 / 545
- 21 -
general [ON/OFF] key and the [KEYLOCK].
When the cook top is off, the key lock function locks all the keys, including the general
[ON/OFF] key.
The key-lock is always activated at the start up of the control.
Fig. 17: Key Lock
13. Relay Ton / Toff for radiant heaters
The relay Ton/ Toff (Duty Cycle) , are shown in the Table.2 depending on the power
level.
Power level
Ton(sec) Toff(sec) Power %
1 1.3 42.7 3.1
2 2.8 41.2 6.3
3 6.2 37.8 14.1
4 8.2 35.8 18.6
5 11 33 25.0
6 13.8 30.2 31.3
7 19.9 24.1 45.3
8 28.2 15.8 64.1
9 44 “ ----- 100
Table 2: Relays Ton/Toff vs. power level
14. Residual heat time calculation for radiant heaters
While a temperature on the cook top glass surface is above 65ºC, this
condition will be shown in the associated display, by means of a “H”.
If the cook top is switched off, the residual heat is shown by a static “H” in the